• Title of article

    Investigation of an innovative method for DC flow suppression of double-inlet pulse tube coolers Original Research Article

  • Author/Authors

    J.Y. Hu، نويسنده , , E.C Luo، نويسنده , , Z.H. Wu، نويسنده , , W. Dai، نويسنده , , S.L. Zhu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    287
  • To page
    291
  • Abstract
    The use of double-inlet mode in the pulse tube cooler opens up a possibility of DC flow circulating around the regenerator and the pulse tube. The DC flow sometimes deteriorates the performance of the cryocooler because such a steady flow adds an unwanted thermal load to the cold heat exchanger. It seems that this problem is still not well solved although a lot of effort has been made. Here we introduce a membrane-barrier method for DC flow suppression in double-inlet pulse tube coolers. An elastic membrane is installed between the pulse tube cooler inlet and the double-inlet valve to break the closed-loop flow path of DC flow. The membrane is acoustically transparent, but would block the DC flow completely. Thus the DC flow is thoroughly suppressed and the merit of double-inlet mode is remained. With this method, a temperature reduction of tens of Kelvin was obtained in our single-stage pulse tube cooler and the lowest temperature reached 29.8 K.
  • Keywords
    Pulse tube cooler , Double-inlet , DC flow , Acoustical transparent membrane
  • Journal title
    Cryogenics
  • Serial Year
    2007
  • Journal title
    Cryogenics
  • Record number