• Title of article

    Constructal design of stack filled with parallel plates in standing-wave thermo-acoustic cooler Original Research Article

  • Author/Authors

    Feng Wu، نويسنده , , Lingen Chen، نويسنده , , Anqing Shu، نويسنده , , Xuxian Kan، نويسنده , , Kun Wu، نويسنده , , Zhichun Yang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    107
  • To page
    111
  • Abstract
    The optimal design for a stack filled with parallel plates in a standing-wave thermo-acoustic cooler was studied for fixed cross-sectional area constraints by using the constructal principle in this paper. The relationship between the cooling load and the plate spacing is derived. These expressions for the optimal plate spacing or the channel size and the optimal plate number are obtained. The results obtained herein shows that in the stack design of a thermo-acoustic cooler, the plate spacing and plate-number should been suitably selected based on the value of L0 and ω so as to obtain the maximum cooling load.
  • Keywords
    Constructal design , Thermo-acoustic cooler , Parallel plates
  • Journal title
    Cryogenics
  • Serial Year
    2009
  • Journal title
    Cryogenics
  • Record number