Title of article
Constructal design of stack filled with parallel plates in standing-wave thermo-acoustic cooler Original Research Article
Author/Authors
Feng Wu، نويسنده , , Lingen Chen، نويسنده , , Anqing Shu، نويسنده , , Xuxian Kan، نويسنده , , Kun Wu، نويسنده , , Zhichun Yang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
5
From page
107
To page
111
Abstract
The optimal design for a stack filled with parallel plates in a standing-wave thermo-acoustic cooler was studied for fixed cross-sectional area constraints by using the constructal principle in this paper. The relationship between the cooling load and the plate spacing is derived. These expressions for the optimal plate spacing or the channel size and the optimal plate number are obtained. The results obtained herein shows that in the stack design of a thermo-acoustic cooler, the plate spacing and plate-number should been suitably selected based on the value of L0 and ω so as to obtain the maximum cooling load.
Keywords
Constructal design , Thermo-acoustic cooler , Parallel plates
Journal title
Cryogenics
Serial Year
2009
Journal title
Cryogenics
Record number
1172900
Link To Document