Abstract
A time-dependent thermo-hydraulic simulation for an ITER toroidal field (TF) coil gradual cool-down to 80 K has been performed using a new FORTRAN code. The code is based on a 1D helium flow and 1D multi-region solid heat conduction model. The whole TF coil is simulated taking into account thermal conduction between winding pack and case, which are cooled down separately. To limit coil mechanical stresses and coolant pressure drop in the cooling channels, an improved cool-down mode has been developed based on the analysis. Typical and gradual cool-down temperature distributions of TF coil and case are presented. The results indicate that gradual cool-down to 80 K can be achieved in 3 weeks.
Keywords
Fusion magnets (F) , Thermodynamics (C) , Cable in conduit conductors (A)