Title of article :
Thermal conductivity of ME771 glass–epoxy laminate from millikelvin temperatures to 4 K
Author/Authors :
Adam L. Woodcraft، نويسنده , , Valentina Martelli، نويسنده , , Guglielmo Ventura، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
3
From page :
52
To page :
54
Abstract :
Permaglas ME771 is a glass–epoxy laminate which is suitable for use at cryogenic temperatures. We have measured the thermal conductivity of a sample of this material between 64 mK and 4.2 K in the direction parallel to the reinforcing fibres, enabling us to make a comparison with the better known material G-10CR. The thermal conductivity follows the form that would be expected for such a material, and is similar to that of G-10CR, which has a similar (room temperature) tensile strength. We comment on some confusion that has arisen over the difference between G-10CR, a material specifically produced for cryogenic use, and G-10, the more common equivalent.
Keywords :
C. Thermal conductivity , D. Instrumentation , A. Structural materials
Journal title :
Cryogenics
Serial Year :
2010
Journal title :
Cryogenics
Record number :
1173016
Link To Document :