Title of article
Experimental studies on pressure drop characteristics of cryogenic cross-counter flow coiled finned tube heat exchangers Original Research Article
Author/Authors
Prabhat Kumar Gupta، نويسنده , , P.K. Kush، نويسنده , , Ashesh Tiwari، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
9
From page
257
To page
265
Abstract
Cross-counter flow coiled finned tube heat exchangers used in medium capacity helium liquefiers/refrigerators were developed in our lab. These heat exchangers were developed using integrated low finned tubes. Experimental studies have been performed to know the pressure drop characteristics of tube side and shell side flow of these heat exchangers. All experiments were performed at room temperature in the Reynolds number range of 3000–30,000 for tube side and 25–155 for shell side. The results of present experiments indicate that available correlations for tube side can not be used for prediction of tube side pressure drop data due to complex surface formation at inner side of tube during formation of fins over the outer surface. Results also indicate that surface roughness effect becomes more pronounced as the value of di/Dm increases. New correlations based on present experimental data are proposed for predicting the friction factors for tube side and shell side.
Keywords
Helium (B) , Heat exchangers (E) , Pressure drop , Experiments , Coiled tube , Finned tube
Journal title
Cryogenics
Serial Year
2010
Journal title
Cryogenics
Record number
1173044
Link To Document