• Title of article

    A 300 Hz two-stage pulse tube cryocooler that attains 58 K

  • Author/Authors

    Huikun Cai، نويسنده , , Luwei Yang، نويسنده , , Ercang Luo a، نويسنده , , Yuan Zhou، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    3
  • From page
    469
  • To page
    471
  • Abstract
    We present a two-stage pulse tube cryocooler working at 300 Hz driven by a thermoacoustic engine. Compared to the previous experimental results, the combined inertance tube with different diameters that is used in the second stage is found to play the key role in phase shifting and to lead to superior cooling. Two different wall thickness tubes are tested in the experiments. After the optimization, the second-stage cold end achieves a no-load temperature of 57.9 K with an average pressure of 3.8 MPa, and a cooling capacity of 0.5 W at 81.88 K.
  • Journal title
    Cryogenics
  • Serial Year
    2010
  • Journal title
    Cryogenics
  • Record number

    1173076