Title of article :
Study on demagnetization characteristics of magnetic shielding plate in cathode ray tube
Author/Authors :
N. Takahashi، نويسنده , , K. Takemoto، نويسنده , , M. Nakano، نويسنده , , K. Shimada، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
An inner magnetic shield (IMS) is set inside a cathode ray tube (CRT) to reduce any external disturbance, and ac demagnetization is applied at every switch on of CRT. In this paper, the problem in measuring an anhysteretic magnetization process is investigated, and the demagnetization characteristics of IMS are measured. It is shown that the Hall probe which is used in a Gauss meter is effective for the accurate measurement of very low dc field, like geomagnetism.
Keywords :
CRT , Demagnetization , Magnetic shielding plate
Journal title :
Journal of Materials Processing Technology
Journal title :
Journal of Materials Processing Technology