Title of article :
Mechanical strength evaluation for Nd-YAG laser and electric resistance spot weld (ERSW) joint under multiaxial loading
Author/Authors :
Haroldo Akira Kavamura، نويسنده , , Gilmar Ferreira Batalha، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
8
From page :
507
To page :
514
Abstract :
This work presents a comparison between laser weld (LBW) and electric resistance spot weld (ERSW) processes used for assemblies of components in a body-in-white (BIW) at a world class automotive industry. It is carried out by evaluating the mechanical strength modeled both by experimental and numerical methods. An “Arcan” multiaxial test was designed and manufactured in order to enable 0°, 45° and 90° directional loadings. The welded specimens were uncoated low carbon steel sheets (Sy = 170 MPa) used currently at the automotive industry, with two different thicknesses: 0.80 and 1.20 mm. A numerical analysis was carried out using the finite element method (FEM) through LS-DYNA code.
Keywords :
Laser weld , Electric resistance spot weld (ERSW) , Car BIW , Arcan test
Journal title :
Journal of Materials Processing Technology
Serial Year :
2008
Journal title :
Journal of Materials Processing Technology
Record number :
1182081
Link To Document :
بازگشت