Title of article :
Generating capacity adequacy evaluation of small stand-alone power systems containing solar energy
Author/Authors :
Roy Billinton، نويسنده , , Bagen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
438
To page :
443
Abstract :
This paper presents a time sequential simulation method for generating capacity adequacy evaluation of small stand-alone power systems containing solar energy (PSCSE) operating in parallel with battery storage. The reliability performance of such a system is quite different from one containing only conventional generation. This is due to the chronological random nature of the solar radiation level and the dependencies associated with the power output of every photovoltaic (PV) generating unit at the site location. The adequacy of a PSCSE depends on various factors such as the solar radiation level, the battery size and charging (discharging) capability, the failure/repair characteristics of the diesel generator (DG) and the PV unit, the system load profile and peak load and the solar energy penetration level in the system etc. The methodologies, results and discussions presented in this paper should provide valuable information to utilities involved in planning and operating stand-alone systems utilizing both conventional and solar energy.
Keywords :
Energy storage , Photovoltaics , Small stand-alone power systems , Generating capacity adequacy
Journal title :
Reliability Engineering and System Safety
Serial Year :
2006
Journal title :
Reliability Engineering and System Safety
Record number :
1187445
Link To Document :
بازگشت