• Title of article

    Is the wear factor in total joint replacements dependent on the nominal contact stress in Tultra-high molecular weight polyethylene contacts

  • Author/Authors

    K.، Vassiliou نويسنده , , Unsworth، A نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    -100
  • From page
    101
  • To page
    0
  • Abstract
    The exact dependence of wear factor on contact stress, load and apparent contact area is much disputed in the literature. This study attempts to solve this dispute. Pin-on-plate studies of ultra high molecular weight polyethylene against stainless steel were conducted under different combinations of load (33-250 N), nominal stress (0.56-12.73 MPa) and face diameter, as well as two tests where both stress and load were kept constant, while the diameter was changed. For these tests the centre of the pin face was bored out to create four different average pin diameters with similar face areas. Diameter and load were found to have no significant effect on the wear factor, while the wear factor decreased with increasing contact stress according to the relation K=2×10^(-6)(sigma)^(-0.84).
  • Keywords
    RAPID TOOLING , HYBRID MANUFACTURING , Rapid prototyping , MULTICOMPONENT PROTOTYPE
  • Journal title
    JOURNAL OF ENGINEERING IN MEDICINE
  • Serial Year
    2004
  • Journal title
    JOURNAL OF ENGINEERING IN MEDICINE
  • Record number