Title of article :
Adaptive use of natural ventilation for thermal comfort in Indian apartments
Author/Authors :
Madhavi Indraganti، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
18
From page :
1490
To page :
1507
Abstract :
Thermal comfort research in India is in its nascent stage. Indian codes specify uniform comfort temperatures between 23 and 26 °C for all types of buildings. About 73% of energy in Indian residences is consumed for ventilation and lighting controls. Therefore, a thermal comfort field survey was conducted in apartment buildings in Hyderabad, which included information on the use of building controls. The present analysis is based on this database. Due to the poor availability of adaptive opportunities, 60% of the occupants were uncomfortable in summer. The comfort range obtained (26.0–32.5 °C) was way above the standard. The occupants adapted through clothing, metabolism and the use of various controls like windows, balcony and external doors and curtains. The subjects operated the controls, as the indoor temperature moved away from the comfort band. At comfort temperature, maximum use of openings was found, which correlated robustly with indoor/outdoor temperature and thermal sensation. Use of controls was critically impeded by lack of privacy and safety and non-availability of controls. Several design and non-thermal factors, such as operation and maintenance of controls, mosquitoes, noise, and occupantʹs attitude, age and tenure impacted the occupantʹs adaptive behaviour and thermal comfort significantly. The buildingʹs ‘restrained adaptive opportunity’ seriously hampered the occupantʹs thermal satisfaction and adversely affected the sensation vote.
Keywords :
Apartments in Hyderabad , Adaptive comfort model , Window opening , Restrained adaptive opportunity , Occupant behaviour , Thermal comfort field survey
Journal title :
Building and Environment
Serial Year :
2010
Journal title :
Building and Environment
Record number :
1217925
Link To Document :
بازگشت