Title of article
Mitigation of cross-contamination in an aircraft cabin via localized exhaust
Author/Authors
Ryan K. Dygert، نويسنده , , Thong Q. Dang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
12
From page
2015
To page
2026
Abstract
Most aircraft cabin ventilation designs currently use a 50% mix of fresh and recirculated, filtered air and supply approximately 8–10 l/s per person. In order to make the most efficient use of the air supply at hand, the 50% of cabin air that is exhausted from the aircraft should remove with it as much contaminant from within the cabin as possible. This will thereby reduce cross-contamination among passengers and improve overall air quality. This study examines the use of localized suction orifices near and around the source occupant to unobtrusively ingest the individual’s thermal plume and exhaust it from the aircraft cabin before contaminants entrained in the plume can significantly mix with the bulk airflow. Through the use of Computational Fluid Dynamics (CFD), various suction seat designs have been tested for their contaminant removal effectiveness and subsequent cross-contamination reduction. CFD results indicate significant improvements over conventional mixing air ventilation systems with a 40–50% decrease in passenger exposure predicted in a conventional coach-class seating arrangement.
Keywords
Aircraft cabin , Indoor air quality , Local Exhaust , Contaminant removal , Personal ventilation
Journal title
Building and Environment
Serial Year
2010
Journal title
Building and Environment
Record number
1217977
Link To Document