Title of article :
The effects of roughness types on friction factors and heat transfer in roughened rectangular duct
Author/Authors :
S.W. Ahn، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
10
From page :
933
To page :
942
Abstract :
A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with ones roughened by five different shapes. The effects of rib shape geometries and Reynolds numbers are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at e/De = 0.0476, P / e = 8, and W /H = 2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones in the range we studied.
Journal title :
International Communications in Heat and Mass Transfer
Serial Year :
2001
Journal title :
International Communications in Heat and Mass Transfer
Record number :
1219535
Link To Document :
بازگشت