Title of article
Two-phase flow structure close to orifice contractions during horizontal intermittent flows
Author/Authors
Marco Fossa، نويسنده , , Giovanni Guglielmini، نويسنده , , Annalisa Marchitto، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
11
From page
698
To page
708
Abstract
Two-phase horizontal intermittent flow through orifice contractions is experimentally investigated by means of a new impedance meter able to collect void fraction data simultaneously at different pipe locations. The investigation focuses on two-phase structure in the region downstream of orifice. Experiments were carried out on horizontal air–water flows in 40 mm inner diameter pipes. Six different orifice plates were considered, as combinations of two restriction ratios and three plate thicknesses. The results demonstrate that the orifices generally induce a marked increase in the downstream void fraction values, and that this is associated to a reduction in film thickness in the stratified regions.
Keywords
Slug frequency , Void fraction , two-phase , Intermittent flow , Orifice contractions
Journal title
International Communications in Heat and Mass Transfer
Serial Year
2006
Journal title
International Communications in Heat and Mass Transfer
Record number
1220069