Title of article :
Thermal characterization of turbulent flow in a channel with isosceles triangular ribs
Author/Authors :
C. Thianpong، نويسنده , , T. Chompookham، نويسنده , , S. Skullong، نويسنده , , P. Promvonge، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
The article presents an experimental investigation on turbulent heat transfer and friction loss behaviors of airflow through a constant heat-fluxed channel fitted with different heights of triangular ribs. The rib cross-section geometry used in the present study was isosceles triangle. Two rib arrangements, namely, in-line and staggered arrays, were introduced. Measurements were carried out for a rectangular channel of aspect ratio, AR = 10 and height, H = 30 mm with three uniform rib heights, e = 4, 6 and 8 mm (e/H = 0.13, 0.2 and 0.26) and one non-uniform rib height, e = 4,6 mm (e/H = 0.13,0.2) alternately for a single rib pitch, P = 40 mm. The flow rate in terms of Reynolds numbers based on the inlet hydraulic diameter of the channel was in a range of 5000 to 22,000. The experimental results show a significant effect of the presence of the ribs on the heat transfer rate and friction loss over the smooth wall channel. The uniform rib height performs better than the corresponding non-uniform one. The in-line rib arrangement provides higher heat transfer and friction loss than the staggered one for a similar mass flow rate. In comparison, the largest e/H rib with inline array yields the highest increase in both the Nusselt number and the friction factor values but the lowest e/H rib with staggered array provides the best thermal performance.
Keywords :
Triangular rib , Rectangular duct , Enhanced heat transfer , Channel flow
Journal title :
International Communications in Heat and Mass Transfer
Journal title :
International Communications in Heat and Mass Transfer