Title of article :
An SHPB set-up with reduced time-shift and pressure bar length
Author/Authors :
H. Meng، نويسنده , , Q.M. Li، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
A modification of split Hopkinson pressure bar (SHPB) set-up based on wave separation technique is proposed in the present paper, which may be used to reduce the time-shifting distance and the pressure bar length in an SHPB test. Incident and reflected strains are separated through two-point strain measurement and the associated iterative formulas. A general error analysis is conducted for the iterative algorithm. The proposed modification of SHPB set-up is examined by using both FE-based numerical simulation and actual SHPB test.
Keywords :
Split Hopkinson pressure bar (SHPB) , Wave separation , FE numerical test
Journal title :
International Journal of Impact Engineering
Journal title :
International Journal of Impact Engineering