Title of article :
Determination of piroxicam in pharmaceutical formulations and urine samples using europium-sensitized luminescence
Author/Authors :
Salma M.Z. Al-Kindy، نويسنده , , Fakhr Eldin O. Suliman، نويسنده , , Aisha A. Al-Wishahi، نويسنده , , Haidar A.J. Al-Lawati، نويسنده , , Muhammed Aoudia، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
A simple, selective and sensitive luminescence method for the assay of piroxicam (PX) in aqueous solution is developed. The method is based on the luminescence sensitization of europium (Eu3+) by formation of ternary complex with PX in the presence of TOPO and Tween-80 as surfactant. The signal for Eu–PX–TOPO is monitored at λex=359 nm and λem=615 nm. Optimum conditions for the formation of the complex in sequential injection analysis (SIA) were 0.01 M Tris buffer, pH 7.5, TOPO 5.0×10−5 M, Tween-80 0.15% and 1.5 mM of Eu3+, which allows the determination of 100–1000 ppb of PX with limit of detection (LOD) of 29 ppb. The relative standard deviations of the method range between 0.5% and 3.9% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assay of PX in pharmaceutical formulations and in urine samples. Average recoveries of 100.8±1.7% was obtained in tablet, whereas a recovery of 97.5±2.0% was obtained for the total PX (PX+hydoxy-PX) in urine sample.
Keywords :
Europium , Piroxicam , Sequential injection , urine , Sensitized luminescence
Journal title :
Journal of Luminescence
Journal title :
Journal of Luminescence