Title of article
Black boxes beget blind spots—How to avoid pitfalls in SPD testing
Author/Authors
François Martzloff، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
8
From page
371
To page
378
Abstract
The current standards for testing surge-protective devices (SPDs), leave some ambiguities for their implementation. Field failure data show that some SPDs that pass standard tests can still fail in unacceptable or unexpected modes, perhaps because of “blind spots” in the test regimen. This paper shows examples of such unresolved issues and progress towards a resolution. It also urges closer attention to the disconnector design, function, and coordination with overcurrent-protective devices in the installation.
Keywords
lightning , SPDtesting , Blindspots , Disconnector , TOV
Journal title
JOURNAL OF ELECTROSTATICS
Serial Year
2007
Journal title
JOURNAL OF ELECTROSTATICS
Record number
1264894
Link To Document