Title of article
Comparison of results for the effective height and atmospheric electric field distribution surrounding a parallelepiped building with Franklinʹs rod and lightning protection rod JUS N. B4. 811
Author/Authors
Sa?a S. Ili?، نويسنده , , Slavoljub R. Aleksic، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
9
From page
616
To page
624
Abstract
Atmospheric electric field distribution in the surroundings of building with lightning protection rod with and without horizontal circular loop is determined in this paper. Lightning protection rod having a circular loop is Serbian national standard (JUS N. B4. 811). The effective height of the building with lightning protection rod, as an important parameter for defining protection area, is also determined. Using the results it is noticed that lightning protection rod having a horizontal circular loop (JUS N. B4. 811) is better than Franklinʹs lightning protection rod, with equal height, for protecting buildings.
Keywords
Effectiveheight , Atmosphericfielddistribution , Perfectconductivematerials(PEC) , Equivalentelectrodesmethod(EEM) , Chargesimulationmethod(CSM)