• Title of article

    Transfer impedance and effectiveness of SMA receptacle for wideband measurement of discharge current due to human ESD

  • Author/Authors

    Yoshinori Taka، نويسنده , , Yoshihisa Kagawa، نويسنده , , Osamu Fujiwara ، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    4
  • From page
    107
  • To page
    110
  • Abstract
    In order to investigate the effectiveness of an SMA receptacle as wideband measurement electrode for human ESD, we derived the transfer impedance of a 50-Ω SMA receptacle, and measured its frequency characteristics from 300 kHz to 20 GHz. With a 12-GHz digital oscilloscope, measurement of discharge currents through a hand-held metal bar from a charged human was made, and thereby the injected currents on the SMA receptacle were reconstructed from the measured transfer impedance. The results show that at a charge voltage of 1500 V the reconstructed current waveform agrees well with the observed voltage waveform divided by 50 Ω.
  • Keywords
    Chargedhuman , SMAreceptacle , Dischargecurrent , Transferimpedance