Title of article :
Measuring of electrostatically induced voltage and its polarity in partially opened metal box by means of neon lamp and photomultiplier tube
Author/Authors :
Norimitsu Ichikawa، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
6
From page :
315
To page :
320
Abstract :
Electronic apparatus in partially opened metal boxes often malfunctions due to electrostatically induced voltage. The induced voltage (induced potential difference, IPD) produces when charged bodies exist and move close. Objectives of this study are (1) to improve the voltage level capable of measuring an induced voltage, (2) to discriminate its polarity. In this study, the IPD and its polarity are demonstrated by means of a neon lamp and a photomultiplier tube. The results will be useful to estimate the value and polarity of the IPD as well as to help with the basic design of printed circuit boards.
Keywords :
Electrostaticallyinducedvoltage , Chargedbody , Partiallyopenedmetalbox , Neonlampandphotomultipliertube
Journal title :
JOURNAL OF ELECTROSTATICS
Serial Year :
2010
Journal title :
JOURNAL OF ELECTROSTATICS
Record number :
1265213
Link To Document :
بازگشت