Title of article :
Transient electric charging of dielectric liquids in recirculation systems
Author/Authors :
David S. Behling، نويسنده , , Behrouz Abedian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
6
From page :
1111
To page :
1116
Abstract :
This paper describes a transient electric charging phenomenon due to flow-induced electrification during a cold startup of dielectric liquids in a recirculation system. This transitory effect exhibits itself as a static voltage spike in the system. It is argued that simultaneous rise in the liquid temperature and the circulation flow rate can generate conditions for such electrostatic voltage spikes to exist. These spikes have been verified experimentally in the laboratory and we report qualitative agreements between the reported experimental data and the theoretical considerations. With a cold start, this transient charging has the potential to induce a large static voltage and large space charge in the circulating system that can damage other components.
Keywords :
Voltagespike , Electrostatic , Engines , filters , Lubricatingoils