Title of article
Humidity in Plant Tissue Culture Vessels
Author/Authors
Chiachung Chen، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
11
From page
231
To page
241
Abstract
The relative humidity within the culture vessels is usually very high, resulting in poorly developed epicuticular wax layer and malfunctioning stomata of the plantlets. In this study, the humidity profile in the plant culture vessel was measured by the high polymer humidity sensor. The accuracy of these sensors was improved by calibration equations established using several saturated salt solutions. The tension of the medium was measured by a piezoresistive silicon tension meter. A vapour transfer model was proposed to describe the factors affecting relative humidity in the vessel. The evaporation model of the medium was established to quantify these factors. Several techniques that had been applied for reducing the relative humidity were evaluated by the vapour transfer model.
Journal title
Biosystems Engineering
Serial Year
2004
Journal title
Biosystems Engineering
Record number
1266525
Link To Document