Title of article :
Response of 45S5 Bioglass® foams to tensile loading
Author/Authors :
L. ?eho?ek، نويسنده , , Z. Chlup، نويسنده , , D. Meng، نويسنده , , D.M. Yunos، نويسنده , , A.R. Boccaccini، نويسنده , , I. DLOUHY، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
6
From page :
8015
To page :
8020
Abstract :
The tensile strength test of highly porous ceramic foams has been developed and first results have been obtained on bioactive glass foams. The tested material was a 45S5 Bioglass® derived foam-like scaffold intended for use in bone tissue engineering which was manufactured by Bioglass® slurry coating of polyurethane foam and subsequent sintering. The Bioglass® foam structure was investigated in two states: uncoated (as fabricated) and with a PDLLA polymer coating. The tensile testing procedure is based on fixation of the foam into aluminium pots by a suitable adhesive. Tensile test samples having cross-section of 10×10 mm2 and a length of 30 mm were used for the experiments. Basic fractographic analysis was applied to get relevant information about specimensʹ behaviour during tensile loading. In Bioglass® based scaffolds, the presence of PDLLA coating led to a significant increase of the fracture strength, which is attributed to the interaction of the polymer phase with propagating cracks, e.g. enabling a crack bridging mechanism to take place.
Keywords :
Foams , Open porosity , tensile strength , Scaffolds , 45S5 Bioglass®
Journal title :
Ceramics International
Serial Year :
2013
Journal title :
Ceramics International
Record number :
1275191
Link To Document :
بازگشت