Title of article :
Evaluation of residual stress in microplasma sprayed hydroxyapatite coating by nanoindentation
Author/Authors :
Arjun Dey، نويسنده , , Anoop K. Mukhopadhyay، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
10
From page :
1263
To page :
1272
Abstract :
The evaluation of residual stress in bioactive hydroxyapatite (HAP) ceramic coating by nanoindentation technique has been attempted successfully for the very first time ever in the present work. The HAP coatings were deposited on surgical grade 316 L austenitic stainless steel and Ti–6Al–4V substrates by microplasma spraying (MIPS) process. The coatings had Ca/P ratio of 1.67 and were ∼80–90% crystalline. The results showed a residual compressive stress of ∼22 MPa for the MIPS-HAP coatings on the SS316L substrates. For the coatings deposited on the Ti–6Al–4V substrates, however, a residual tensile stress of ∼11 MPa was estimated. These data matched well with those obtained by XRD based technique. Thus, favorable data comparison provides further support to the efficacy of the nanoindentation based technique utilized in the present work for residual stress estimations.
Keywords :
Hydroxyapatite , Coating , Microplasma spraying , Residual stress , Nanoindentation
Journal title :
Ceramics International
Serial Year :
2014
Journal title :
Ceramics International
Record number :
1275615
Link To Document :
بازگشت