Title of article :
Dynamic characteristics of a R-410A split air-conditioning system
Author/Authors :
Kim، نويسنده , , Man-Hoe and Bullard، نويسنده , , Clark W، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
8
From page :
652
To page :
659
Abstract :
This paper presents experimental results on the shut-down and start-up characteristics of a residential split system R-410A air-conditioner with a capillary tube. During shut-down, the transient characteristics are evaluated by measuring the high and low side pressures and temperatures of the system. The dynamic behavior of the system after start-up is also investigated at the standard cooling capacity rating condition of which the dry and wet bulb temperatures for the indoor and outdoor are 27/19.5 and 35/24°C, respectively. All experiments are performed in a psychrometric calorimeter. The cooling capacity, power consumption, dehumidification capacity and cycle characteristics after start-up are analyzed. The test results show that the cooling capacity and the coefficient of performance (COP) after start-up can be expressed as the combination of two exponential functions of time, approaching the cooling capacity of steady-state.
Keywords :
Frigorigène , R410A , Capillaire , Fonctionnement , Performance , Air conditioner , Air conditioining , Tout ou rien , R410A , capillary , Operation , Performance , Shut-down , start-up , Condionnement dיair , Conditionneur dיair , Refrigerant
Journal title :
International Journal of Refrigeration
Serial Year :
2001
Journal title :
International Journal of Refrigeration
Record number :
1338922
Link To Document :
بازگشت