Title of article :
The effect of micro-scale surface treatment on heat and mass transfer performance for a falling film H2O/LiBr absorber
Author/Authors :
Kim، نويسنده , , Jin-Kyeong and Park، نويسنده , , Chan Woo and Kang، نويسنده , , Yong Tae، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
The objectives of this paper are to develop a new method of wettability measurement, to study the effect of micro-scale surface treatment on the wettability across horizontal tubes and to apply it for numerical analysis of heat and mass transfer in a H2O/LiBr falling film absorber. Three types of tubes with roughness are tested in a test rig. Inlet solution temperature (30–50 °C), concentration (55–62 wt.% of LiBr) and mass flow rate (0.74–2.71 kg/min) are considered as key parameters. Reynolds number ranged from 30 to 120 by controlling the inlet mass flow rate. The wettability on the roughened tubes was higher than that for the smooth tubes. The wettability decreased linearly along the vertical location but was proportional to the solution temperature and mass flow rate. The experimental correlations of the wettability for the smooth and the roughened tubes were developed with error bands of ±20 and ±10%, respectively. These are used for the heat and mass transfer analysis of absorbers with micro-scale hatched tubes.
Keywords :
Film tombant , Tube horizontal , surface , Transfert de chaleur , Absorption System , Absorber , Falling Film , Transfert de masse , Système à absorption , Mass transfer , heat transfer , surface , Treatment , Traitement , Horizontal tube , Absorbeur
Journal title :
International Journal of Refrigeration
Journal title :
International Journal of Refrigeration