Title of article
Strengthening of a bridge pier capbeam using bonded FRP composite plates
Author/Authors
Osman Hag-Elsafi and Sreenivas Alampalli، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
11
From page
393
To page
403
Abstract
Application of fiber reinforced polymer (FRP) composite plates to strengthen the capbeam of Pier 3 of East Church Street Bridge in Chemung County, New York, is discussed in this paper. Addition of a concrete wearing surface and a median barrier to the bridge superstructure increased dead load, contributing to deficiencies in moment and shear capacities of the capbeam structure. As a result, the concrete capbeam suffered flexural and shear cracking, and was considered for strengthening using bonded FRP composite plates. Service load tests were performed before and after the plates were installed, to investigate effectiveness of the strengthening system. Installation of the plates and results from the performed load tests related to flexural behavior of the beam are discussed in the paper.