Title of article :
Dynamic behavior of a direct expansion evaporator under frosting condition. Part II. Field investigation on a shipping container
Author/Authors :
Tso، نويسنده , , C.P. and Cheng، نويسنده , , Y.C. and Lai، نويسنده , , A.C.K.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A field investigation is performed on the frost formation at an evaporator of a commercial full-scale refrigerated container that uses R-12 as the working refrigerant. Results when compared with those from a numerical model presented earlier show that the model is capable of predicting the dynamic behavior of a direct expansion evaporator under both non-frosting and frosting conditions. The air outlet and energy transferred compare well between experiment and model, and within 20% for the air pressure drop. The frost occurrence and propagation agree well generally, with the frost formation first occurring at the first row where the refrigerant enters the evaporator.
Keywords :
Refrigerated container , Marine transport , Experiment , Evaporator , finned tube , Frost formation , Performance , ةvaporateur , Expérimentation , Conteneur frigorifique , Tube alieté , Transport maritime , Performance , Givrage
Journal title :
International Journal of Refrigeration
Journal title :