Title of article :
An experimental investigation on performance of bubble pump with lunate channel for absorption refrigeration system
Author/Authors :
Zhang، نويسنده , , Lianying and Wu، نويسنده , , Yuyuan and Zheng، نويسنده , , Hongfei and Guo، نويسنده , , Jingang and Chen، نويسنده , , Dongsheng، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
8
From page :
815
To page :
822
Abstract :
An experimental research on the performance of the bubble pump for absorption refrigeration units was made. The bubble pump provides the drive for the absorption cycle and is a decisive component of the absorption refrigeration unit. The bubble pumpʹs property determines the efficiency of the absorption refrigeration system. A continuous experimental system with different size of bubbles pumps were designed, constructed and successfully worked. The experiments were performed by changing some of the parameters affecting the bubble pump performance. The experimental results shows that the performance of the bubble pump depends mainly on the driving temperature, the solution head and the combining tube diameters. With the suitable size of section area of the pump tubes the net elevating height of solution is 2.5 times as high as the solution submergence. The lunate channel has several outstanding characteristics, such as low starting temperature (minimum 68 °C), wide operating temperature range and lower requirement for vacuum condition (under 10 kPa). Then the elevating capability of the bubble pump with lunate channel is much better than others currently. It would provide well foundation for practical applications.
Keywords :
Calcul , Absorption System , Experiment , PUMP , Geometry , Système à absorption , CALCULATION , Expérimentation , Pompe , Géométrie , Bulle , Bubble
Journal title :
International Journal of Refrigeration
Serial Year :
2006
Journal title :
International Journal of Refrigeration
Record number :
1341262
Link To Document :
بازگشت