Title of article
A study of accurate latent heat measurement for a PCM with a low melting temperature using T-history method
Author/Authors
Peck، نويسنده , , Jong Hyeon and Kim، نويسنده , , Jae-Jun and Kang، نويسنده , , Chaedong and Hong، نويسنده , , Hiki، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
8
From page
1225
To page
1232
Abstract
When the latent heat of a phase change material (PCM) with a lower melting point than ambient temperature was assessed according to the standard T-history method using a vertically oriented test tube, a temperature gradient occurred in the longitudinal direction of the tube due to natural convection. This led to a decrease in the accuracy of the latent heat of fusion measurement. In this study, the accuracy of the measurement with the original T-history method was improved without decreasing the testʹs simplicity and convenience by setting the test tube horizontally. The heat transfer to the vapor-layer of the tube under volume change during melting was assumed to be negligible and the results were calculated using the two inflection points of temperature as the start and end of latent heat period. Under these assumptions, the results agree closely with other reference data. And, the new method proposed in this study showed a remarkable reduction in data scattering.
Keywords
low temperature , Température , melting , Measurement , latent heat , porous medium , Recherche , history , Temperature , Matériau , Basse température , Fusion , Mesure , Material , Milieu poreux , changement de phase , Research , chaleur latente , phase change , Historique
Journal title
International Journal of Refrigeration
Serial Year
2006
Journal title
International Journal of Refrigeration
Record number
1341413
Link To Document