Title of article
Refrigerating machine operating characteristics under various mixed refrigerant mass charges
Author/Authors
Rozhentsev، نويسنده , , Andrey، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
11
From page
1145
To page
1155
Abstract
This paper reports the results of experimental investigation of a low-temperature Joule–Thomson refrigerating machine, working by use of a non-azeotropic mixture of refrigerants and with a single-stage hermetic compressor. The temperature, hydraulic and power performance of the machine are determined experimentally in relation to the mixed refrigerant (MR) mass charge. Variations of the MR refrigerating machine operating performance with the working mixture mass charge are found to be considerably different from the analogous performance variations of a refrigerating machine charged with a pure refrigerant. The peculiarities of those relationships are analyzed theoretically. The specific value of a minimum acceptable MR mass charge for the investigated system and its correlation with internal processes in the machine loop are established as well. If the refrigerant mixture mass charges are below the minimum ones, the temperature and power performance of the MR machine differ essentially from the design performance and such operating modes are considered inadmissible.
Keywords
Performance , Système frigorifique , Système à compression , Parameter , Compresseur hermétique , Mélange non azéotropique , Performance , Charge en frigorigène , Refrigerant charge , Expérimentation , Refrigeration system , Paramètre , Compression system , Non-azeotropic mixture , Hermetic compressor , Experiment
Journal title
International Journal of Refrigeration
Serial Year
2008
Journal title
International Journal of Refrigeration
Record number
1341834
Link To Document