Performance of diffusion absorption refrigeration cycle with organic working fluids
Author/Authors
Zohar، نويسنده , , A. and Jelinek، نويسنده , , M. and Levy، نويسنده , , A. and Borde، نويسنده , , I.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
6
From page
1241
To page
1246
Abstract
A diffusion absorption refrigeration (DAR) cycle is driven by heat and utilizes a binary solution of refrigerant and absorbent as working fluid, together with an auxiliary inert gas. Commercial DAR systems operate with ammonia–water solution and hydrogen or helium as the inert gas. In this work, the performance of a simplified DAR system working with an organic absorbent (DMAC – dimethylacetamide) and five different refrigerants and helium as inert gas was examined numerically, with the aim of lowering the generator temperature and system pressure along with a non-toxic refrigerant The refrigerants were: chlorodifluoromethane (R22), difluoromethane (R32), 2-chloro-1,1,1,2-tetrafluoroethane (R124), pentafluoroethane (R125) and 1,1,1,2-tetrafluoroethane (R134a). The results were compared with the performance of the same system working with ammonia–water and helium. Similar behavior was found for all systems, regarding the coefficient of performance (COP) and rich and poor solution concentrations as functions of generator temperature. It was found that typical generator temperature with the new substances was 150 °C, yet lower COPs, higher evaporator temperatures and lower condensation temperature of about 40 °C governed these systems.
Keywords
R22 , R32 , R124 , R125 , R22 , R134a , R32 , Hélium , R124 , comparaison , R134a , Absorption System , Helium , Diffusion system , Ammonia–water , Performance , Système à absorption , Système à diffusion , Calcul , Performance , R125 , Ammoniac–eau , comparison , CALCULATION
Journal title
International Journal of Refrigeration
Serial Year
2009
Journal title
International Journal of Refrigeration
Record number
1342335
Link To Document