Title of article :
PVT measurements of water-ammonia refrigerant mixture in the critical and supercritical regions
Author/Authors :
Polikhronidi، نويسنده , , N.G. and Abdulagatov، نويسنده , , I.M. and Batyrova، نويسنده , , R.G. and Stepanov، نويسنده , , G.V.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
17
From page :
1897
To page :
1913
Abstract :
The PVTx properties of H2O + NH3 mixture (0.2607 mole fraction of ammonia) have been measured in the near- and supercritical regions. Measurements were made along 40 liquid and vapor isochores in the range from 120.03 to 727.75 kg m−3 and at temperatures from 301 to 634 K and at pressures up to 28 MPa. Temperatures and densities at the liquid–gas phase transition curve, dew- and bubble-pressure points, and the critical parameters for the 0.7393 H2O + 0.2607 NH3 mixture were obtained using the quasi-static thermograms and isochoric (P–T) break-point techniques. The expanded uncertainty of the density, pressure, temperature measurements at the 95% confidence level with a coverage factor of k = 2 is estimated to be 0.06%, 0.02–0.09%, and 15 mK, respectively.
Keywords :
critical point , Frigorigène , Ammoniac/eau , Expérimentation , Refrigerant , Température , Masse volumique , aqueous solution , Point critique , Pression , Solution aqueuse , Mesure , Ammonia/water , Experiment , Measurement , Pressure , Density , Temperature
Journal title :
International Journal of Refrigeration
Serial Year :
2009
Journal title :
International Journal of Refrigeration
Record number :
1342422
Link To Document :
بازگشت