Title of article
Performance optimization of dual-loop cycles using R-600a and hydrocarbon mixtures designed for a domestic refrigerator-freezer
Author/Authors
Yoon، نويسنده , , Won Jae and Seo، نويسنده , , Kookjeong and Chung، نويسنده , , Hyun Joon and Kim، نويسنده , , Yongchan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
11
From page
1657
To page
1667
Abstract
A dual-loop cycle for a domestic refrigerator-freezer (RF) has a large energy saving potential because it has a lower compression ratio due to a higher evaporating temperature in the fresh food compartment (R)-operation compared to a conventional refrigeration cycle, as well as individual optimization flexibility for each loop. In this study, optimizations of dual-loop cycles using R-600a and hydrocarbon (HC) mixtures were individually carried out. Each optimization process included both a theoretical analysis and an experimental investigation. The theoretical analysis was conducted to optimize the specifications of cycle components and the HC mixture compositions for each loop. Based on the experimental results, the energy consumptions of the optimized dual-loop cycles using R-600a and HC mixtures were decreased by 14.2% and 18.6%, respectively, compared with that of a bypass two-circuit cycle using R-600a in the same RF platform.
Keywords
Optimisation , Réfrigérateur domestique , Hydrocarbon , Performance , Non-azeotropic mixture , optimization , Household refrigerator , Hydrocarbure , Mélange non-azéotropique , Performance