• Title of article

    Flow regime based calibration of a capacitive void fraction sensor for small diameter tubes

  • Author/Authors

    De Kerpel، نويسنده , , K. and Ameel، نويسنده , , B. and TʹJoen، نويسنده , , C. and Canière، نويسنده , , H. and De Paepe، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    12
  • From page
    390
  • To page
    401
  • Abstract
    The void fraction measurement technique used in this work is based on measuring the capacity between two electrodes. The electrodes are curved so they closely fit to the tube wall; due to this the measured capacitance is influenced by the spatial distribution of the phases and not only the void fraction. Hence, the measured capacitance does not linearly vary with the void fraction. In this work a method is proposed to account for the distribution of the phases and thus determine the void fraction based on capacitive measurements. The proposed method was applied to 270 measurement points. The tube diameter D is 8 mm, the mass flux ranges from 200 to 500 kg m−2s−1 and the vapour fraction ranges between 2.5% and 97.5%. Refrigerants R134a and R410A were used. The results were compared to the Steiner version of the Rouhani–Axelsson drift flux void fraction model. A very good agreement with this model was observed.
  • Keywords
    Void fraction , écoulement diphasique , Flow regime , capacitance , régime dיécoulement , taux de vide , capacitance , Two-phase flow
  • Journal title