Title of article
Flow regime based calibration of a capacitive void fraction sensor for small diameter tubes
Author/Authors
De Kerpel، نويسنده , , K. and Ameel، نويسنده , , B. and TʹJoen، نويسنده , , C. and Canière، نويسنده , , H. and De Paepe، نويسنده , , M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
12
From page
390
To page
401
Abstract
The void fraction measurement technique used in this work is based on measuring the capacity between two electrodes. The electrodes are curved so they closely fit to the tube wall; due to this the measured capacitance is influenced by the spatial distribution of the phases and not only the void fraction. Hence, the measured capacitance does not linearly vary with the void fraction. In this work a method is proposed to account for the distribution of the phases and thus determine the void fraction based on capacitive measurements. The proposed method was applied to 270 measurement points. The tube diameter D is 8 mm, the mass flux ranges from 200 to 500 kg m−2s−1 and the vapour fraction ranges between 2.5% and 97.5%. Refrigerants R134a and R410A were used. The results were compared to the Steiner version of the Rouhani–Axelsson drift flux void fraction model. A very good agreement with this model was observed.
Keywords
Void fraction , écoulement diphasique , Flow regime , capacitance , régime dיécoulement , taux de vide , capacitance , Two-phase flow
Journal title
International Journal of Refrigeration
Serial Year
2013
Journal title
International Journal of Refrigeration
Record number
1345122
Link To Document