• Title of article

    Experimental testing of an oil-flooded hermetic scroll compressor

  • Author/Authors

    Bell، نويسنده , , Ian H. and Groll، نويسنده , , Eckhard A. and Braun، نويسنده , , James E. and Horton، نويسنده , , W. Travis، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    8
  • From page
    1866
  • To page
    1873
  • Abstract
    In this work, a residential air conditioning compressor designed for vapor injection has been modified in order to inject large quantities of oil into the working chamber in order to approach an isothermal compression process. The compressor was tested with oil injection mass flow fractions of up to 45%. At an evaporating temperature of −10 °C and condensing temperature of 30 °C, the overall isentropic efficiency was up to 70% at the highest oil injection rate. Overall, over the testing envelope investigated, there are no significantly negative effects experienced for the compressor and the compressor isentropic efficiency and refrigerant mass flow rate improve monotonically as the oil injection rate is increased.
  • Keywords
    air conditioning , Refrigeration , Flooded compression , Conditionnement dיair , compression noyée , Froid
  • Journal title
    International Journal of Refrigeration
  • Serial Year
    2013
  • Journal title
    International Journal of Refrigeration
  • Record number