Title of article :
Critical heat flux under zero flow conditions in vertical annulus with uniformly and non-uniformly heated sections
Author/Authors :
Chun، Se-Young نويسنده , , Moon، Sang-Ki نويسنده , , Chung، Heung-June نويسنده , , Yang، Sun-Kyu نويسنده , , Chung، Moon-Ki نويسنده , , ARITOMI، MASANORI نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2001
Pages :
-264
From page :
265
To page :
0
Abstract :
The experimental study of water CHF (critical heat flux) under zero flow conditions has been carried out in an annulus flow channel with uniformly and non-uniformly heated sections over a pressure range of 0.52-14.96 MPa. In the present boiling system, the CHFs occur in the upper region of the heated section, in contrast to the results in the experiments for boiling tubes conducted by several investigators. The general trend of the CHF with pressure is that the CHF increases up to a medium pressure of about 6-8 MPa and decreases as the pressure is further increased. A comparison of the present data with the existing flooding CHF correlations shows that the correlations depend greatly on the effect of the heat flux distribution. When the correction terms with the density ratio and the effect of the heat flux distribution proposed in the present work are used with the CHF correlation based on the Wallis flooding correlation, it predicts the measured flooding CHF within an RMS error of 9.0%.
Keywords :
Hippocampus , AMPA receptor , NMDA receptor , Fluctuations , Synaptic plasticity
Journal title :
Nuclear Engineering and Design
Serial Year :
2001
Journal title :
Nuclear Engineering and Design
Record number :
13544
Link To Document :
بازگشت