Title of article
An electrochemical hydrogen meter for measuring hydrogen in sodium using a ternary electrolyte mixture
Author/Authors
Sridharan، نويسنده , , R. and Mahendran، نويسنده , , K.H. and Nagaraj، نويسنده , , S. and Gnanasekaran، نويسنده , , T. and Periaswami، نويسنده , , G.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
6
From page
10
To page
15
Abstract
An electrochemical sensor for measuring hydrogen concentration in liquid sodium that is based on a ternary mixture of LiCl, CaCl2 and CaHCl as the electrolyte has been developed. DSC experiments showed the eutectic temperature of this ternary system to be ∼725 K. Impedance spectroscopic analysis of the electrolyte indicated ionic conduction through a molten phase at ∼725 K. Two electrochemical hydrogen sensors were constructed using the ternary electrolyte of composition 70 mol% LiCl:16 mol% CaHCl:14 mol% CaCl2 and tested at 723 K in a mini sodium loop and at hydrogen levels of 60–250 ppb in sodium. The sensors show linear response in this concentration range and are capable of detecting a change of 10 ppb hydrogen in sodium over a background level of 60 ppb. Identification of this electrolyte system and its use in a sensor for measuring hydrogen in sodium are described in this paper.
Journal title
Journal of Nuclear Materials
Serial Year
2003
Journal title
Journal of Nuclear Materials
Record number
1356898
Link To Document