Title of article :
Specimen size effects on the compressive strength and Weibull modulus of nuclear graphite of different coke particle size: IG-110 and NBG-18
Author/Authors :
Chi، نويسنده , , Se-Hwan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
6
From page :
185
To page :
190
Abstract :
The effects of specimen size on the compressive strength and Weibull modulus were investigated for nuclear graphite of different coke particle sizes: IG-110 and NBG-18 (average coke particle size for IG-110: 25 μm, NBG-18: 300 μm). Two types of cylindrical specimens, i.e., where the diameter to length ratio was 1:2 (ASTM C 695-91 type specimen, 1:2 specimen) or 1:1 (1:1 specimen), were prepared for six diameters (3, 4, 5, 10, 15, and 20 mm) and tested at room temperature (compressive strain rate: 2.08 × 10−4 s−1). Anisotropy was considered during specimen preparation for NBG-18. The results showed that the effects of specimen size appeared negligible for the compressive strength, but grade-dependent for the Weibull modulus. In view of specimen miniaturization, deviations from the ASTM C 695-91 specimen size requirements require an investigation into the effects of size for the grade of graphite of interest, and the specimen size effects should be considered for Weibull modulus determination.
Journal title :
Journal of Nuclear Materials
Serial Year :
2013
Journal title :
Journal of Nuclear Materials
Record number :
1362173
Link To Document :
بازگشت