Title of article :
Measurement of hydrogen absorption in flowing liquid lithium in the flowing lithium retention experiment (FLIRE)
Author/Authors :
Stubbers، نويسنده , , R. and Olczak، نويسنده , , W. and Nieto، نويسنده , , M. and Ruzic، نويسنده , , D.N.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
5
From page :
1033
To page :
1037
Abstract :
Flowing metal plasma facing components (PFCs) have the ability to withstand the extreme conditions of future tokamaks. The FLIRE facility at the University of Illinois measures the retention properties, both for helium (ash pumping) and hydrogen (recycling regime, tritium inventory), of candidate liquid PFCs, such as lithium. Results of hydrogen absorption measurements in flowing liquid lithium are presented. Absorption experiments with a flowing lithium stream passing through a low-pressure neutral deuterium gas show 0.1–0.2% D concentration retained long-term in the sample. A similar experiment with a high deuterium pressure of approximately 1 Torr shows the same long-term deuterium retention. These values indicate that the deuterium absorption rate is limited by the dissociation rate of the molecular deuterium gas on the Li surface.
Keywords :
thermal desorption , Divertor material , Hydrides , Liquid metal , lithium
Journal title :
Journal of Nuclear Materials
Serial Year :
2005
Journal title :
Journal of Nuclear Materials
Record number :
1362266
Link To Document :
بازگشت