• Title of article

    Performance evaluation of reverse osmosis technology for selected antibiotics removal from synthetic pharmaceutical wastewater

  • Author/Authors

    Gholami، Mitra نويسنده 1Depatment of Environmental Engineering, School of Public Health, Center for Water Quality Research, Tehran University of Medical Sciences, Tehran, Iran , , Mirzaei، Roya نويسنده 1Depatment of Environmental Engineering, School of Public Health, Center for Water Quality Research, Tehran University of Medical Sciences, Tehran, Iran , , Rezaei Kalantary، Roshanak نويسنده Department of Environmental Health, School of Health, Tehran University of Medical Sciences, Tehran, Iran. Rezaei Kalantary, Roshanak , Sabzali، Ahmad نويسنده Department of Environmental Health Engineering, School of Public Health, Isfahan University of Medical Sciences, Isfahan, Iran , , Gatei، Fateme نويسنده 1Depatment of Environmental Engineering, School of Public Health, Center for Water Quality Research, Tehran University of Medical Sciences, Tehran, Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی 12 سال 2012
  • Pages
    10
  • From page
    1
  • To page
    10
  • Abstract
    This study addresses the possibility for low pressure reverse osmosis membrane (RE 2521, CSM) process to serve as an alternative to remove selected antibiotics (ampicillin and amoxicillin) from synthetic wastewater by changing operating conditions such as pH = 3, 6.5 and 10; Pressure = 9, 11 and13 (bar); antibiotic concentration = 10, 255 and 500(mg/L), and temperature = 20, 30 and 40°C. The experiment was designed based on Box-benken, which is a Response Surface methodology design (RSM), using Design Expert software. The concentration of antibiotics was measured by applying a UV-spectrophotometer (Cecil), at the wavelength of 254 nm. Results showed a range of rejection percentage from 73.52% to 99.36% and 75.1% to 98.8%, for amoxicillin and ampicillin, respectively. Considering the solute rejections and the membrane porosity show that the prevailing rejection mechanism of the examined antibiotics by the membrane was the size exclusion effect. The permeate flux for both of the antibiotics was 12–18.73 L/m2.h. Although the permeate flux and antibiotic rejection are influenced by operating pressure, pH, and temperature individually, the interaction between operating parameters did not have noticeable effects. According to the results obtained in this study, the application of RO membrane is recommended for the selected antibiotics to be removed to a considerable degree (up to 95%).
  • Journal title
    Iranian Journal of Environmental Health Science and Engineering (IJEHSE)
  • Serial Year
    2012
  • Journal title
    Iranian Journal of Environmental Health Science and Engineering (IJEHSE)
  • Record number

    1364413