Title of article
Damage evaluation under thermal fatigue of a vertical target full scale component for the ITER divertor
Author/Authors
Missirlian، نويسنده , , M. and Escourbiac، نويسنده , , F. and Merola، نويسنده , , M. and Durocher، نويسنده , , A. and Bobin-Vastra، نويسنده , , I. and Schedler، نويسنده , , B.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
1330
To page
1336
Abstract
An extensive development programme has been carried out in the EU on high heat flux components within the ITER project. In this framework, a Full Scale Vertical Target (VTFS) prototype was manufactured with all the main features of the corresponding ITER divertor design. The fatigue cycling campaign on CFC and W armoured regions, proved the capability of such a component to meet the ITER requirements in terms of heat flux performances for the vertical target. This paper discusses thermographic examination and thermal fatigue testing results obtained on this component. The study includes thermal analysis, with a tentative proposal to evaluate with finite element approach the location/size of defects and the possible propagation during fatigue cycling.
Journal title
Journal of Nuclear Materials
Serial Year
2007
Journal title
Journal of Nuclear Materials
Record number
1365694
Link To Document