• Title of article

    Dissolution of uranium metal without hydride formation or hydrogen gas generation

  • Author/Authors

    Soderquist، نويسنده , , Chuck and McNamara، نويسنده , , Bruce and Oliver، نويسنده , , Brian، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    6
  • From page
    299
  • To page
    304
  • Abstract
    This study shows that metallic uranium will cleanly dissolve in carbonate-peroxide solution without generation of hydrogen gas or uranium hydride. Metallic uranium shot, 0.5–1 mm diameter, was reacted with ammonium carbonate–hydrogen peroxide solutions ranging in concentration from 0.13 M to 1.0 M carbonate and 0.50 M to 2.0 M peroxide. The dissolution rate was calculated from the reduction in bead mass, and independently by uranium analysis of the solution. The calculated dissolution rate ranged from about 4 × 10−3 to 8 × 10−3 mm/h, dependent primarily on the peroxide concentration. Hydrogen analysis of the etched beads showed that no detectable hydrogen was introduced into the uranium metal by the etching process.
  • Journal title
    Journal of Nuclear Materials
  • Serial Year
    2008
  • Journal title
    Journal of Nuclear Materials
  • Record number

    1367033