Title of article
Double-supply-frequency pressure pulsation in annular linear induction pump Part 1: Measurement and numerical analysis
Author/Authors
Araseki، Hideo نويسنده , , Kirillov، lgor R. نويسنده , , Preslitsky، Gennady V. نويسنده , , Ogorodnikov، Anatoly P. نويسنده ,
Issue Information
دوهفته نامه با شماره پیاپی سال 2000
Pages
-84
From page
85
To page
0
Abstract
This paper describes an experimental and analytical study of double-supply-frequency pressure pulsation arising in an annular linear induction pump. In a large-scale induction pump, it is known that the supply frequency should be relatively low in order to satisfy a magnetohydrodynamic stability criterion. Under such a low supply frequency, however, double-supply-frequency pressure and flow rate pulsation generated in an induction pump may be of concern. The experimental data obtained in the present work shows that the amplitude of the pressure pulsation increases with decreasing supply frequency, number of poles and/or slip. The numerical result reveals that the pressure pulsation comes from a disturbance of the electromagnetic force near the staler ends.
Keywords
Participation , Problem solving , Production , Change , Renewal , Working conditions