Title of article
Assessment of portable emission measurement systems (PEMS) for heavy-duty diesel engines with respect to particulate matter
Author/Authors
Mamakos، نويسنده , , Athanasios and Bonnel، نويسنده , , Pierre and Perujo، نويسنده , , Adolfo and Carriero، نويسنده , , Massimo، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2013
Pages
17
From page
54
To page
70
Abstract
The performance of three Portable Emission Measurement Systems (PEMS) for Particulate Matter (PM) was assessed in our laboratory against reference instrumentation in engine dynamometer testing of five Heavy Duty Engines (HDEs) of different aftertreatment technologies. The candidate systems were designed around the minimum requirements of allowing a gravimetric determination of the total emitted PM mass and incorporating a real time particle sensor. All PEMS-PM systems were found to reproduce within ±30% the gravimetric PM results determined with reference measurement systems under non-regenerative operating conditions, at emission levels lying at and above the Euro VI limit of 10 mg/kWh. The use of prolonged sampling times envisaged in In Service Conformity (ISC) testing (>120 min) was found to be beneficial, as it reduced the limit of detection of the PEMS-PM instrumentation to 1–3 mg/kWh (120 min) from 3 to 9 mg/kWh (30 min). The real time aerosol instrumentation exhibited a much higher sensitivity, being capable of quantifying emission levels below the EURO VI particle number limit of 6×1011 #/kWh. Some modifications were required though in two particle sensors that were based on diffusion charging, in order to avoid a disproportional increase in their responses in the presence of homogeneously nucleated particles. Passive regeneration of the particulate filter resulted in excessive emission of volatile PM but also large discrepancies between the PEMS-PM and reference systems. The accurate quantification of absolute emission levels of non-volatile PM from the real time sensors can assist in the identification of such excessive volatile PM fractions, to avoid properly working DPF systems to fail an ISC test.
Keywords
PEMS , PM , In service conformity , Moving average window
Journal title
Journal of Aerosol Science
Serial Year
2013
Journal title
Journal of Aerosol Science
Record number
1386228
Link To Document