• Title of article

    Portable mass spectrometry for measurement of anaesthetic agents and methane in respiratory gases

  • Author/Authors

    Turner، نويسنده , , P.G. and Dugdale، نويسنده , , A. and Young، نويسنده , , I.S. and Taylor، نويسنده , , S.، نويسنده ,

  • Issue Information
    فصلنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    36
  • To page
    44
  • Abstract
    Monitoring the composition of gases breathed by anaesthetised patients requires measurement methods with fast responses, high accuracy and good reliability. There is also an increasing demand for systems to be able to monitor more than one target analyte simultaneously, but some gas analysers can be sensitive to the presence of methane gas in exhaled breath, consequently leading to inaccurate measurements of the anaesthetic agent. This study investigated the feasibility of employing portable quadrupole mass spectrometry to monitor volatile anaesthetic agents (halothane, isoflurane and sevoflurane), methane accumulation in anaesthetic rebreathing systems, and inspired and exhaled carbon dioxide and oxygen concentrations during equine anaesthesia in a clinical setting. The volatile anaesthetic agents were easily measurable and methane was detectable. The instrument had an advantage over short wavelength infrared absorption spectrometry analysers because it could monitor anaesthetic agents and other respiratory gases simultaneously and at extremely low concentrations, although further optimisation is required.
  • Keywords
    Horse , equine , Volatile anaesthetic agents , Methane , Quadrupole mass spectrometry
  • Journal title
    The Veterinary Journal
  • Serial Year
    2008
  • Journal title
    The Veterinary Journal
  • Record number

    1392542