Author/Authors :
Hiramatsu، نويسنده , , K. and Matsui، نويسنده , , T. and Ito، نويسنده , , A. and Miyakita، نويسنده , , T. and OSADA، نويسنده , , Y. and Yamamoto، نويسنده , , T.، نويسنده ,
Abstract :
Aircraft noise measurements were recorded at the residential areas in the vicinity of Kadena Air Base, Okinawa in 1968 and 1972 at the time of the Vietnam war. The estimated equivalent continuous A-weighted sound pressure level LAeq for 24 h was 85 dB.The time history of sound level during 24 h was estimated from the measurement conducted in 1968, and the sound level was converted into the spectrum level at the centre frequency of the critical band of temporary threshold shift (TTS) using the results of spectrum analysis of aircraft noise operated at the airfield. With the information of spectrum level and its time history, TTS was calculated as a function of time and level change. The permanent threshold shift was also calculated by means of Robinsonʹs method and ISOʹs method. The results indicate the noise exposure around Kadena Air Base was hazardous to hearing and is likely to have caused hearing loss to people living in its vicinity.