Title of article :
Evaluation of maxillary arterial blood flow in anesthetized cats with the mouth closed and open
Author/Authors :
Barton-Lamb، نويسنده , , A.L. and Martin-Flores، نويسنده , , M. and Scrivani، نويسنده , , P.V. and Bezuidenhout، نويسنده , , A.J. and Loew، نويسنده , , E. and Erb، نويسنده , , H.N. and Ludders، نويسنده , , J.W.، نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی سال 2013
Pages :
7
From page :
325
To page :
331
Abstract :
The mouth-gag is a common tool used in veterinary medicine during oral and transoral procedures in cats but its use has recently been associated with the development of blindness. The goal of this study was to investigate whether maximal opening of the mouth affects maxillary artery blood flow in six anesthetized cats. To assess blood flow, the electroretinogram (ERG), brainstem auditory evoked response (BAER) and magnetic resonance angiography (MRA) were evaluated qualitatively with the mouth closed and open. During dynamic computer tomography (CT) examinations, detection of contrast medium in the maxillary artery was quantified by measuring the Hounsfield units (HUs). The peak HU, time to peak and mean HU were determined. Changes ⩾10% of these parameters were considered indicative of altered blood flow.
Keywords :
Deafness , blindness , Magnetic resonance angiography , FELINE , Maxillary artery , Dynamic CT