Title of article :
Fracture assessment of shallow-flaw cruciform beams tested under uniaxial and biaxial loading conditions
Author/Authors :
Bass، B.R. نويسنده , , McAfee، W.J. نويسنده , , Williams، P.T. نويسنده , , Pennell، W.E. نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 1999
Pages :
-258
From page :
259
To page :
0
Abstract :
A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow, surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a far-field, out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for an RPV material. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies, namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness; the conventional maximum principal stress criterion indicated no effect. A three-parameter Weibull model based on the hydrostatic stress criterion is shown to correlate with the experimentally observed biaxial effect on cleavage fracture toughness by providing a scaling mechanism between uniaxial and biaxial loading states. © 1999 Elsevier Science S.A. All rights reserved.
Keywords :
Specimen reconstitution , Fracture toughness , Charpy specimens , Compact tension specimens
Journal title :
Nuclear Engineering and Design
Serial Year :
1999
Journal title :
Nuclear Engineering and Design
Record number :
14014
Link To Document :